Sphygmomanometers for Self-measurement of Blood Pressure (SBPM)

| UPPER ARM DEVICES | WRIST DEVICES | COMMUNITY DEVICES |

The following tables are lists of currently available Upper Arm and Wrist devices for Self-measurement of Blood Pressure and Devices for Measuring Blood Pressure in the Community. Discontinued devices are shown on a separate table. A complete list of all devices is available on our Device Index.

Upper Arm Devices for Self-measurement of Blood Pressure

New to the marketNew to the website FTS: Study evaluated prior to publication using the dabl®Educational Fast Track validation Service
Device Mode AAMI BHS ESH 2002 ESH 2010 Circumstance Recommendation Ref  
A&D UA-631 (UA-779 Life Source) Osc     Pass   At rest, Recruitment violations Recommended 4  
A&D UA-651 Osc       Pass Study (96) extended to ESH-IP 2010 requirements Recommended 97
A&D UA-704 Osc   A/A     Study details omitted Questionable 8  
A&D UA-705 Osc   A/A     At rest Recommended 18  
A&D UA-767 Osc Pass A/A     At rest; not high BP Recommended 3  
A&D UA-774
(UA-767 Plus)
Osc   A/A     At rest; tables incomplete Recommended 11  
  A/A     At rest; Recruitment violations; Simultaneous readings Questionable 2   
A&D UA-778 Osc Pass B/A     Children Only, Ad hoc protocol adaptation. (No general validation) Recommended 53  
A&D UA-787 Osc     Pass     Recommended 6  
A&D UA-853 Osc     Pass   Minor recruitment modification Recommended 46  
A&D UA-1020 Osc   A/A     D-ring 22cm to 32cm cuff Recommended 84  
  A/A     Cylindrical 17cm to 32cm cuff Recommended 84  
Andon KD-391 Osc (Semi-Auto)     Pass   At rest Recommended 56  
Andon KD-556 Osc     Pass   KD-5915 Equivalence Recommended E42  
Andon KD-575 Osc     Fail   At rest Not Recommended 59  
Andon KD-5031 Osc     Pass   KD-5915 Equivalence Recommended E43  
Andon KD-5913 Osc     Pass   KD-5915 Equivalence Recommended E45  
Andon KD-5915 Osc     Pass   At rest Recommended 57  
Andon KD-5917 Osc       Pass At rest Recommended 95
Andon KD-5963 Osc     Pass   KD-5915 Equivalence Recommended E44  
Andon MD-534 Osc     Pass   KD-5915 Equivalence Recommended E46  
Beurer BM35 Osc     Pass   HL-868BA Equivalence Recommended E67  
Beurer BM44 Osc     Pass   KD-5915 Equivalence Recommended E68  
Beurer BM47 Osc     Pass   KD-5915 Equivalence Recommended E105  
Beurer BM58 Osc     Pass   KD-5915 Equivalence Recommended E78  
Beurer BM60 Osc     Pass   DS-400 Equivalence Recommended E69  
Beurer BM65 Osc     Pass   KD-5915 Equivalence Recommended E79  
Beurer SBM43 Osc     Pass   KD-5915 Equivalence Recommended E80  
Beurer SBM45 Osc     Pass   KD-5915 Equivalence Recommended E81  
BIOS BD204 Osc     Pass   LD-578 Equivalence Recommended E74  
BIOS BD209 Osc     Pass   LD-578 Equivalence Recommended E66  
Braun BP4600 Osc     Pass   HL-868BA Equivalence Recommended E35  
Braun BP4900 Osc     Pass   HL-868BA Equivalence Recommended E40  
Braun BP5900 Osc     Pass   HL-868BA Equivalence Recommended E41  
Braun BP6000 Osc     Pass   TMB-986 Equivalence Recommended E95  
Braun BP6100 Osc     Pass   TMB-986 Equivalence Recommended E96  
Braun BP6200 Osc     Pass   TMB-986 Equivalence Recommended E97  
Citizen CH-432B Osc     Pass   At rest Recommended 40  
Citizen CH-452 Osc     Pass   CH-432B Equivalence Recommended E73  
Colson MAM BP3AA1-2 Osc     Pass   At rest Recommended 16  
Foracare Fora D 30 Osc     Pass   At rest Recommended 72  
Foracare Fora D 40b Osc       Pass At rest Recommended 75  
Foracare Fora P30 Plus Osc       Pass At rest Recommended 82  
Foracare Fora P80 Diamond Cuff BP
(Fora Test N'Go BP)
Osc       Pass At rest Recommended 94
Hartmann Tensoval Duo Control Aus-Osc Pass A/A Pass   At rest Recommended 45  
Hartmann Tensoval Duo Control II Aus-Osc Pass A/A   Pass* *ESH-IP 2010 in Aus mode only Recommended 87  
Health & Life HL-868BA Osc     Pass   At rest Recommended 44  
Health & Life HL-888HA Osc   Pass     Abstract; Protocol adjustments Questionable 21  
  A/A     At rest Recommended 26  
Honsun LD-30 Osc     Pass   LD-578 Equivalence Recommended E66  
Honsun LD-578 Osc     Pass   At rest Recommended 47  
IEM
Stabil-O-Graph
Osc   A/A Pass   At rest Recommended 27   
iHealth BP3 (KD-931) Osc       Pass At rest Recommended 70  
    Pass   KD-5915 Equivalence Recommended E60  
iHealth BP5 Osc       Pass At rest Recommended 85  
Kingyield BP101H Osc     Pass   At rest Recommended 60  
Lloyds Pharmacy BP11 Osc     Pass   At rest Recommended 58  
Medel Check (92187) Osc     Pass   KD-5915 Equivalence Recommended E64  
Medel Elite (92125) Osc     Pass   KD-5915 Equivalence Recommended E65  
Medel Idea (91913 IDEA) Osc Pass A/A Pass   SAA-102 Equivalence Recommended E33  
Medipro MediCare 100f Osc       Pass At rest (Note: Not IBP Medipro 100f) Recommended 68  
Microlife BP 3AC1-1 Osc     Pass   At rest Recommended 15  
Pass A/A     Pregnancy; Abstract Questionable 20   
Pass B/A     Pre-eclampsia; Abstract Questionable 20   
Microlife BP 3AC1-1 PC Osc     Pass   BP 3AC1-1 Equivalence Recommended E1  
    Pass   ESRD population Recommended 28  
Microlife BP 3AC1-2 Osc     Pass   BP 3AC1-1 Equivalence Recommended E2  
Microlife BP 3AG1 Osc   A/A     BP 3BT0-A Equivalence Recommended E3  
Microlife BP 3BT0-1 Osc   A/A     BP 3BT0-A Equivalence
Recommended E4  
Microlife BP 3BT0-A Osc   A/A     Small recruitment violation Recommended 7  
Pass A/B     Normotensive Pregnancy Recommended 12  
Pass B/B     Non-proteinuric HBP
Pass A/B     Pre-Eclampsia
Microlife BP 3BT0-A(2) Osc   A/A     BP 3BT0-A Equivalence Recommended E5  
Microlife BP 3BT0-AP Osc   A/A     BP 3BT0-A Equivalence Recommended E6  
Microlife BP A1 Easy (BP3GR1-1P) Osc   A/A Pass   BP A100 Plus and BP 3BT0-A Equivalences Recommended E106  
Pass A/B     Normotensive Pregnancy
Pass B/B     Non-proteinuric HBP
Pass A/B     Pre-Eclampsia
Microlife BP A2 Basic (BP3GQ1-3P) Osc   A/A Pass   BP A100 Plus and BP 3BT0-A Equivalences Recommended E107  
Pass A/B     Normotensive Pregnancy
Pass B/B     Non-proteinuric HBP
Pass A/B     Pre-Eclampsia
Microlife BP A6 PC (BP3GU1-8Y) Osc   A/A Pass   BP A100 Plus and BP 3BT0-A Equivalences Recommended E108  
Pass A/B     Normotensive Pregnancy
Pass B/B     Non-proteinuric HBP
Pass A/B     Pre-Eclampsia
Microlife BP A100 Osc     Pass   BP A100 Plus Equivalence Recommended E7  
    Pass   With M-L Soft Cuff Recommended FTS, 52  
    Pass   With M-L Rigid Conical Cuff Recommended 37  
Microlife BP A100 Plus Osc     Pass   At rest Recommended 17  
    Pass   At rest Recommended 29  
Microlife Exact BP (BP3MD1-3) Osc     Pass   BP A100 Equivalence Recommended E21  
Microlife RM 100 Osc   A/A     BP 3BT0-A Equivalence Recommended E8  
Microlife WatchBP Home (BP3MX1-1) Osc     Pass   At rest Recommended 25  
  A/A     Pregnancy Recommended 66  
  B/A     Pre-Eclampsia Recommended 66  
Microlife WatchBP Home A (BP3MX1-3) Osc     Pass   Watch BP Home Equivalence Recommended E27  
Microlife WatchBP Home N (BP3MX1-4) Osc     Pass   Watch BP Home Equivalence Recommended E70  
Microlife WatchBP Home S (BP3MX1-5) Osc     Pass   Watch BP Home Equivalence Recommended E28  
Microlife WatchBP O3 (3MZ0) Osc     Pass   At rest Recommended 61  
Microlife WatchBP O3 (3MZ1) Osc     Pass   At rest Recommended 62  
Nissei DS-400 Osc     Pass   At rest Recommended 48  
Nissei DS-500 Osc     Pass   DS-400 Equivalence Recommended E38  
Nissei DSK-1011 Osc       Pass At rest Recommended 76  
Nissei DSK-1031 Osc       Pass At rest Recommended 77  
Nissei DSK-1051 Osc       Pass DSK-1031 Equivalence Recommended E98  
Omron 705IT
(HEM-759-E)
Osc     Pass     Recommended 9  
Pass A/A     Minor recruitment modification Recommended 14  
    Pass   Children and adolescents. Reasonable adaptation of protocol. Recommended 22  
Omron 708-BT
(HEM-7081-ITE)
Osc Pass A/A     M7 (HEM-780-E) Equivalence Recommended E103  
Omron BP760
(HEM-7220-Z)
Osc     Pass   M6 Comfort (HEM-7000-E) Equivalence
New sensor
Recommended E87  
Omron BP785
(HEM-7222-Z)
Osc     Pass   M6 Comfort (HEM-7000-E) Equivalence
New sensor
Recommended E88  
Omron HEM-705CP-II
(HEM-759-E2)
Osc     Pass   705IT (HEM-759-E) Equivalence Recommended E12  
Omron HEM-746C
(HEM-746C-SH)
Osc     Pass   M2 Compact (HEM-7102-E) Equivalence Recommended E54  
Omron HEM-780REL Osc     Pass   At rest; "East Wrap" cuff. Poor study and paper Questionable 32  
Omron HEM-1020 Osc     Pass   Supplementary Results Recommended 71  
Omron HEM-7051
(HEM-7051-SH)
Osc     Pass   M3 Intellisense (HEM-7051-E) Equivalence Recommended E48  
Omron HEM-7080IC Osc Pass A/A Pass   705IT (HEM-759-E) Equivalences Recommended E20  
Omron HEM-7101
(HEM-7101-SH)
Osc     Pass   M2 Compact (HEM-7102-E) Equivalence Recommended E53  
Omron HEM-7130 (Japanese model) Osc       Pass At rest Recommended 88  
Omron HEM-7250-IT Osc       Pass HEM-7251G Equivalence Recommended E102  
Omron HEM-7251G Osc       Pass At rest Recommended 83  
Omron HEM-7320F Osc       Pass At rest Recommended 89  
Omron HEM-7500F Osc       Pass At rest Recommended 90  
Omron HEM-Solar
(HEM-4500-SOLE)
Osc     Pass   M1 Plus (HEM-4011C-E) Equivalence Recommended E26  
Omron IA2
(HEM-7011-C1)
Osc Pass A/A Pass   705IT (HEM-759-E) Equivalence Recommended E13  
Omron i-C10
(HEM-7070-E)
Osc     Pass   M6 Comfort (HEM-7000-E) Equivalence Recommended E18  
Pass A/A     M7 (HEM-780-E) Equivalence Recommended E19  
Omron i-Q132 SpotArm
(HEM-1010-E)
Osc     Pass   Supplementary Results Recommended 71  
Omron i-Q142 SpotArm
(HEM-1040-E)
Osc       Pass At rest Recommended 81  
Omron M1
(HEM-4030-E)
Osc     Pass   M1 Plus (HEM-4011C-E) Equivalence Recommended E59  
Omron M1 Classic
(HEM-442-E)
Osc     Pass   M1 Plus (HEM-4011C-E) Equivalence Recommended E10  
Omron M1 Compact
(HEM-4022-E)
Osc     Pass   M1 Plus (HEM-4011C-E) Equivalence Recommended E11  
Omron M1 Plus
(HEM-4011C-E)
Osc     Pass   At rest Recommended 29  
Omron M2
(HEM-7117-E)
Osc     Pass   M3 Intellisense (HEM-7051-E) Equivalence Recommended E49  
Omron M2
(HEM-7117-E8)
Osc     Pass   M3 Intellisense (HEM-7051-E) Equivalence
New sensor
Recommended E83  
Omron M2
(HEM-7119-E)
Osc     Pass   M3 Intellisense (HEM-7051-E) Equivalence
New sensor
Recommended E90  
Omron M2
(HEM-7121-E)
Osc       Pass HEM-7130 (Japanese model) Equivalence Recommended E112  
Omron M2 Basic
(HEM-7116-E)
Osc     Pass   M3 Intellisense (HEM-7051-E) Equivalence Recommended E50  
Omron M2 Basic
(HEM-7116-E2)
Osc     Pass   M3 Intellisense (HEM-7051-E) Equivalence
New sensor
Recommended E89  
Omron M2 Basic
(HEM-7116-E8)
Osc     Pass   M3 Intellisense (HEM-7051-E) Equivalence
New sensor
Recommended E82  
Omron M2 Basic
(HEM-7120-E)
Osc       Pass HEM-7130 (Japanese model) Equivalence Recommended E111  
Omron M2 Compact
(HEM-7102-E)
Osc     Pass   At rest Recommended 31  
Omron M3
(HEM-7131-E)
Osc       Pass M6 AC (HEM-7322-E) Equivalence Recommended E113  
Omron M3
(HEM-7200-E)
Osc     Pass   M3 Intellisense (HEM-7051-E) Equivalence Recommended E51  
      Pass Supplementary Results Recommended 65  
Omron M3
(HEM-7200-E2)
Osc     Pass   M3 Intellisense (HEM-7051-E) Equivalence
New sensor
Recommended E91  
Omron M3
(HEM-7200-E8)
Osc     Pass   M3 Intellisense (HEM-7051-E) Equivalence
New sensor
Recommended E84  
Omron M3 Intellisense
(HEM-7051-E)
Osc     Pass   At rest Recommended 31  
Omron M3 IT
(HEM-7131U-E)
Osc       Pass M6 AC (HEM-7322-E) Equivalence Recommended E114  
Omron M3W
(HEM-7202-E)
Osc       Pass At rest Recommended 78  
Omron M4-I
(HEM-752-E)
Osc Pass A/A Pass   705IT (HEM-759-E) Equivalence Recommended E15  
Omron M5-I
(HEM-757-E)
Osc     Pass     Recommended 9  
    Pass   Elderly Population Recommended 33  
Omron M6
(HEM-7001-E)
Osc     Pass   At rest Recommended 19  
    Pass   General Population Recommended 34  
    Pass   Obese Population Recommended 34  
    Pass   Elderly Population Recommended 23  
Pass A/A     705IT (HEM-759-E) Equivalence Recommended E23  
Omron M6
(HEM-7211-E)
Osc Pass A/A Pass   705IT (HEM-759-E) Equivalences Recommended E58  
      Pass Supplementary Results Recommended 65  
Omron M6
(HEM-7211-E8)
Osc     Pass   705IT (HEM-759-E) Equivalence
New sensor
Recommended E85  
Omron M6 AC
(HEM-7322-E)
Osc       Pass At rest Recommended 93  
Omron M6 Comfort
(HEM-7000-E)
Osc     Pass   At rest Recommended 29  
Pass A/A     M7 (HEM-780-E) Equivalence Recommended E17  
Omron M6 Comfort
(HEM-7221-E)
Osc     Pass   M6 Comfort (HEM-7000-E) Equivalence Recommended E56  
Pass A/A     M7 (HEM-780-E) Equivalence Recommended E57  
Omron M6 Comfort
(HEM-7221-E8)
Osc       Pass At rest Recommended 80  
    Pass   M6 Comfort (HEM-7000-E) Equivalence
New sensor
Recommended E86  
Omron M6 Comfort
(HEM-7223-E)
Osc       Pass M6 Comfort (HEM-7221-E8) Equivalence Recommended E92  
Omron M6 Comfort
(HEM-7321-E)
Osc       Pass At rest Recommended 92  
Omron M6 Comfort IT
(HEM-7322U-E)
Osc       Pass M6 Comfort (HEM-7321-E) Equivalence Recommended E115  
Omron M6W
(HEM-7213-E)
Osc       Pass At rest Recommended 79  
Omron M7
(HEM-780-E)
Osc Pass A/A     General population Recommended 38  
    Pass   Population requiring Large Cuff Recommended 35  
  A/A     Pregnancy Recommended 50  
  B/B     Pre-Eclampsia Recommended 50  
Omron M10-IT
(HEM-7080IT-E)
Osc     Pass   M6 Comfort (HEM-7000-E) Equivalence Recommended E16  
Pass A/A     M7 (HEM-780-E) Equivalence Recommended E9  
Omron MX2 Basic
(HEM-742-E2)
Osc     Pass   M2 Compact (HEM-7102-E) Equivalence Recommended E55  
Omron MX3 Plus
(HEM-742-E)
Osc     Pass   Subject to corrected tables being published Recommended 13, FTS  
Omron SEM-1
(HEM-7051-C12)
Osc     Pass   M3 Intellisense (HEM-7051-E) Equivalence Recommended E52  
Oregon Scientific BPU 330 Osc     Pass   At rest, Plots incorrect Recommended 49  
Oregon Scientific BPW810       Pass   At rest Questionable 24  
Panasonic EW3106 Osc     Pass   At rest Recommended 69, FTS  
Panasonic EW3109 Osc     Pass   At rest Recommended 69, FTS  
Pic Solution (Artsana)
Pic Indolor (Artsana)
Classic Check (100)
Osc     Pass   My Check Equivalence Recommended E30  
Pic Solution (Artsana)
Pic Indolor (Artsana)
Classic Check (200)
Osc     Pass   My Check Equivalence Recommended E72  
Pic Solution (Artsana)
Pic Indolor (Artsana)
Comfort Check
Osc     Pass   At rest Recommended 54  
Pic Solution (Artsana)
Pic Indolor (Artsana)
CS 410
Osc     Pass   At rest Recommended 41  
Pic Solution (Artsana)
Pic Indolor (Artsana)
CSI 610
Osc     Pass   At rest Recommended 39  
Pic Solution (Artsana)
Pic Indolor (Artsana)
Daily Check
Osc     Pass   My Check Equivalence Recommended E75  
Pic Solution (Artsana)
Pic Indolor (Artsana)
Digit Extra
Osc     Pass   KD-5915 Equivalence Recommended E93  
Pic Solution (Artsana)
Pic Indolor (Artsana)
Digit Smart
Osc     Pass   KD-5915 Equivalence Recommended E94  
Pic Solution (Artsana)
Pic Indolor (Artsana)
Help Check
Osc     Pass   My Check Equivalence Recommended E76  
Pic Solution (Artsana)
Pic Indolor (Artsana)
Mamy Check
Osc     Pass   My Check Equivalence Recommended E77  
Pic Solution (Artsana)
Pic Indolor (Artsana)
My Check
Osc     Pass   At rest Recommended 54  
Pic Solution (Artsana)
Pic Indolor (Artsana)
One Check
Osc     Pass   My Check Equivalence Recommended E31  
Pic Solution (Artsana)
Pic Indolor (Artsana)
Personal Check
Osc     Pass   At rest Recommended 54  
Polygreen K-Jump
KP-7770
Osc     Pass   K-Jump KP7500D Equivalence Recommended E71  
Rossmax ME 701 series Osc   A/A Pass   At rest Recommended 30  
Seinex SE-9400 Osc     Pass   At rest Recommended 15  
Sensacare SAA-102 (Standard) Osc Pass A/A Pass   Three studies. BHS under reported. Recommended 36  
Spengler K-Jump
KP7500D
Osc     Pass   At rest Recommended 29  
Spengler K-Jump
Pro M
Osc     Pass   At rest Recommended 42  
Taidoc U-Right TD-3124 Osc       Pass At rest Recommended 91  
Thermor Bios BD215 Osc       Pass At rest Recommended 86  
Transtek TMB-986 Osc     Pass   At rest Recommended 67  
UEBE Visomat Comfort 20/40 Osc     Pass   At Rest Recommended 43  
UEBE Visomat Comfort E (Ref 24016) Osc       Pass Double Comfort (Osc Mode) Equivalence Recommended E104  
UEBE Visomat Comfort Eco Osc     Pass   At rest Recommended 51  
UEBE Visomat Comfort Form Osc     Pass   At rest Recommended 55  
UEBE Visomat Double Comfort Osc       Pass At rest Recommended 6474  
Aus       Pass At rest Recommended 6373
Welch-Allyn transtelephonic home monitor Osc Pass ?     Parkinson's disease, 30 sub * 2 measurements Questionable 5  

* Note: Grading criteria had not been established though BHS protocol was in operation.5

References for Validation of Upper Arm Devices for Self-measurement of Blood Pressure

1 Dieterle T, Battegay E, Bucheli B, Martina B. Accuracy and 'range of uncertainty' of oscillometric blood pressure monitors around the upper arm and wrist. Blood Press Monit 1998;3:339-46
2 Kobalava ZD, Kotovskaia IV, Rusakova OS, Babaeva LA. Validation of UA-767 Plus device for self measurement of blood pressure. Clin Pharmacol Ther 2003;12 (2):70-2
3 Rogoza AN, Pavlova TS, Sergeeva MV. Validation of A&D UA-767 device for the self-measurement of blood pressure. Blood Press Monit 2000;5(4):227-31
4 Longo D, Bertolo O, Toffanin G, Frezza P, Palatini P. Validation of the A&D UA-631 (UA-779 Life Source) device for self-measurement of blood pressure and relationship between its performance and large artery compliance. Blood Press Monit 2002;7:243-8
5 Herbst T, Anis-Anwar Y, Giacco S, White W. Evaluation of the overall system precision of the Welch-Allyn transtelephonic home blood pressure monitor in adults with Parkinson's disease. Blood Press Monit 2002;7:285-8
6 Longo D, Toffanin G, Garbelotto R, Zaetta V, Businaro L, Palatini P. Performance of the UA-787 oscillometric blood pressure monitor according to the European Society of Hypertension Protocol. Blood Press Monit 2003;8:91-5
7 Cuckson AC, Reinders A, Shabeeh H, Shennan AH. Validation of the Microlife BP 3BTO-A oscillometric blood pressure monitoring device according to a modified British Hypertension Society protocol. Blood Press Monit 2002;7(6):319-24
8 Koblava ZD, Kotovskaya YV, Rodionov E Validation of semi-automatic device UA-704 for self-measurement of blood pressure. Blood Press Monit 2005;10:223-5
9 El Assad M, Topouchian J, Asmar R. Evaluation of two devices for self-measurement of blood pressure according to the international protocol: the Omron M5-I and the Omron 705IT. Blood Press Monit 2003;8(3):127-33
11 Verdecchia P, Angeli F, Poeta F, Reboldi GP, Borgioni C, Pittavini L, Porcellati C. Validation of the A&D UA774 (UA-767Plus) device for self measurement of blood pressure. Blood Press Monit 2004;9:225-9
12 Reinders A, Cuckson AC, Lee JTM, Shennan AH. An accurate automated blood pressure device for use in pregnancy and pre-eclampsia: the Microlife 3BTO-A. BJOG 2005;112(7):915-20
13 Coleman A, Freeman P, Steel S, Shennan A Validation of the Omron MX3 Plus oscillometric blood pressure monitoring device according to the European Society of Hypertension international protocol. Blood Press Monit 2005;10:165-8
14 Coleman A, Freeman P, Steel S, Shennan A. Validation of the Omron 705IT (HEM-759-E) oscillometric blood pressure monitoring device according to the British Hypertension Society protocol. Blood Press Monit 2006;11:27-32
15 Topouchian JA, El Assad MA, Orobinskaia LV, El Feghali RN, Asmar RG. Validation of two devices for self-measurement of brachial blood pressure according to the International Protocol of the European Society of Hypertension: the Seinex SE-9400 and the Microlife BP 3AC1-1. Blood Press Monit 2005;10:325-31
16 Pereira T, Maldonado J. Validação de aparelho de medição automática da pressão arterial Colson MAM BP3AA1-2 segundo o Protocolo da Sociedade Europeia de Hipertensão. Rev Port Cardiol 2005;24(11):1341-51
17 Stergiou GS, Giovas PP, Neofytou MS, Adamopoulos DN. Validation of the Microlife BP A 100 Plus device for self-home blood pressure measurement according to the International. Protocol Blood Press Monit 2006;11:157-60
18 Verdecchia P, Angeli F, Gattobigio R, Angeli E, Pede S, Pittavini L. Validation of the A&D UA-705 device for self-measurement of blood pressure according to the British Hypertension Society protocol. Blood Press Monit 2006;11:223-7
19 Topouchian JA, El Assaad MA, Orobinskaia LV, El Feghali RN, Asmar RG. Validation of two automatic devices for self-measurement of blood pressure according to the International Protocol of the European Society of Hypertension: the Omron M6 (HEM-7001-E) and the Omron R7 (HEM 637-IT). Blood Press Monit 2006;11:165-71
20 de Greeff A, Reggiori F, Anthony J, Shennan A. The Microlife 3AC1: An accurate blood pressure measurement device in pregnancy and pre-eclampsia [abstract]. J Hypertens 2006;24(suppl 4):S279 Abstract P14.475
21 Tholl U, Assouline E. Validation of the automatic arm type non-invasive blood pressure monitor HL-888HA [abstract].J Hypertens 2006;24(suppl 4):S285 Abstract P14.496
22 Stergiou GS, Yiannes NG, Rarra VC. Validation of the Omron 705 IT oscillometric device for home blood pressure measurement in children and adolescents: The Arsakion School Study. Blood Press Monit 2006,11:229-34
23 Altunkan S, Iliman N, Altunkan E. Validation of the Omron M6 (HEM-7001-E) upper arm blood pressure measuring device according to the International Protocol in elderly patients. Blood Press Monit 2008;13:117-22
24 Li L, Wang Hui W, Jin Lan W. Validation of the Oregon Scientific BPW810 blood pressure monitor according to the European Society of Hypertension Protocol. Blood Press Monit 2006;11:343-7
25 Stergiou GS, Giovas PP, Charilaos P. Gkinos CP, Patouras JD. Validation of the Microlife WatchBP Home device for self home blood pressure measurement according to the International Protocol. Blood Press Monit 2007;12:185-8
26 de Greeff A, Shennan AH. The Health and Life device (HL888HA): accuracy assessment in an adult population according to the British Hypertension Society protocol. Blood Press Monit 2007;12:107-11
27 Westhoff TH, Schmidt S, Zidek W, van der Giet M. Validation of the Stabil-O-Graph blood pressure self-measurement device. Journal of Human Hypertension 2007;22:233-5 (Research Letter)
28 Thompson AM, Eguchi K, Reznik ME, Shah SS, Pickering TG. Validation of an oscillometric home blood pressure monitor in an end-stage renal disease population and the effect of arterial stiffness on its accuracy. Blood Press Monit 2007;12:227-32
29 Belghazi J, El Feghali RN, Moussalem T, Rejdych M, Asmar RG. Validation of four automatic devices for self-measurement of blood pressure according to the International Protocol of the European Society of Hypertension. Vascular Health and Risk Management 2007;3(4):389-400
30 de Greeff A, Shennan AH. The Rossmax (ME 701 series) upper arm device: accuracy assessment in an adult population according to the International and the British Hypertension Society protocols. Blood Press Monit 2008;13:43-8
31 Asmar R, Khabouth J, Topouchian J, El Feghali R, Mattar J. Validation of three automatic devices for self-measurement of blood pressure according to the International Protocol: The Omron M3 Intellisense (HEM-7051-E), the Omron M2 Compact (HEM 7102-E), and the Omron R3-I Plus (HEM 6022-E). Blood Press Monit 2010;15(1):49-54
32 Viera AJ, Hinderliter AL. Validation of the HEM-780REL with easy wrap cuff for self-measurement of blood pressure according to the European Society of Hypertension International Protocol. Blood Press Monit 2007;12:335-8
33 Omboni S, Riva I, Giglio I, Caldara G, Groppelli A, Parati G. Validation of the Omron M5-I, R5-I and HEM-907 automated blood pressure monitors in elderly individuals according to the International Protocol of the European Society of Hypertension. Blood Press Monit 2007;12:233-42
34 Altunkan S, Iliman N, Kayaturk N, Altunkan E. Validation of the Omron M6 (HEM-7001-E) upper-arm blood pressure measuring device according to the International Protocol in adults and obese adults. Blood Press Monit 2007;12:219-25
35 El Feghali RN, Topouchian JA, Pannier BM, El Assaad HA, Asmar RG. Validation of the Omron M7 (HEM-780-E) blood pressure measuring device in a population requiring large cuff use according to the International Protocol of the European Society of Hypertension. Blood Press Monit 2007;12:173-8
36 Zaetta V, Daniele L, Perkovic D, Prattico F, Barisa M, Perfetti P, Gabrieli A, Buonocore F, Winnicki M. Validation of the SAA-102 home blood pressure monitor according to the protocols of the European Society of Hypertension, the Association for the Advancement of Medical Instrumentation and the British Society of Hypertension. Blood Press Monit 2007;12:363-8
37 Bonso E, Saladini F, Zanier A, Benetti E, Dorigatti F, Palatini P. Accuracy of a single rigid conical cuff with standard-size bladder coupled to an automatic oscillometric device over a wide range of arm circumferences. Hypertens Res. 2010;33(11):1186-91.
38 Coleman A, Steel S, Freeman P, de Greeff A, Shennan A. Validation of the Omron M7 (HEM-780-E) oscillometric blood pressure monitoring device according to the British Hypertension Society protocol. Blood Press Monit 2008;13:49-54
39 Pini C, Pastori M, Baccheschi J, Omboni S, Parati G. Validation of the Artsana CSI 610 automated blood pressure monitor in adults according to the International Protocol of the European Society of Hypertension. Blood Press Monit 2007;12:179-84
40 Cotte UV, Faltenbacher VH, von Willich W, Bogner JR. Trial of validation of two devices for self-measurement of blood pressure according to the European Society of Hypertension International Protocol: the Citizen CH-432B and the Citizen CH-656C. Blood Press Monit 2008;13:55-62
41 Pini C, Natalizi A, Gerosa PF, Frigerio M, Omboni S, Parati G. Validation of the Artsana CS 410 automated blood pressure monitor in adults according to the International Protocol of the European Society of Hypertension. Blood Press Monit 2008;13:177-82
42 de Greeff A, Ahmed N, Sheppard E, Andrew H. Shennan AH. A self-measurement device suitable for hospital use: validation of the Spengler Pro M according to the International Protocol of the European Society of Hypertension. Blood Press Monit 2008;13:183-6
43 Stergiou GS, Tzamouranis D, Nasothimiou EG, Protogerou AD. Can an electronic device with a single cuff be accurate in a wide range of arm size? Validation of the Visomat Comfort 20/40 device for home blood pressure monitoring. Journal of Human Hypertension 2008;23:Advanced Online Publication
44 Chen HE, Cui Y, Sheng CS, Li LH, Li Y, Wang JG. Validation of the Health & Life HL868BA blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol. Blood Press Monit 2008;13:305-8
45 de Greeff A, Arora J, Hervey S, Liu B, Shennan AH. Accuracy assessment of the Tensoval duo control according to the British and European Hypertension Societies' standards. Blood Press Monit 2008;13:111-6
46 Bonso E, Ragazzo F, Palatini P. Validation of A&D UA-85X device for blood pressure measurement. Blood Press Monit 2008;13:339-341
47 Zhang Y, Wang J, Huang QF, Sheng CS, Li Y, Wang JG. Validation of the HONSUN LD-578 blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol. Blood Press Monit 2009;14:128-31
48 Duhig KE, de Greeff A, van der Westhuizen A, Baker E, Shennan AH. Validation of the Nissei DS-400 in a low-resource setting. Blood Press Monit 2009;14:132-5
49 Li L, Zhang XY, Yan CH, Liang QX. Validation of the Oregon Scientific BPU 330 for self-monitoring of blood pressure according to the International Protocol. Vascular Health and Risk Management 2008;4(5):1121-5
50 de Greeff A, Beg Z, Gangji Z, Dorney E, Shennan AH. Accuracy of inflationary versus deflationary oscillometry in pregnancy and preeclampsia: OMRON-MIT versus OMRON-M7. Blood Press Monit 2009;14:37-40
51 Perkovic D, Guarnieri C, Palatini P. Validation of the visomat comfort eco blood pressure measuring device according to the International Protocol. Blood Press Monit 2009;14:178-80
52 Bonso E, Dorigatti F, Palatini P. Accuracy of the BP A100 blood pressure measuring device coupled with a single cuff with standard-size bladder over a wide range of arm circumferences. Blood Press Monit 2009;14:216-9
53 Narogan MV, Narogan MI, Syutkina EV. Validation of A&D UA-778 blood pressure monitor in children. Blood Press Monit 2009;14:228-31
54 Germano G, Psimenos A, Sarullo F, Venditti A, Pecchioli V, Asmar R. Validation of four automatic devices for self-measurement of blood pressure according to the International Protocol: The Pic Indolor Personal Check, Comfort Check, My Check and Travel Check. Blood Pressure 2009;18 (Suppl 1):15-23
55 Bonso E, Dorigatti F, Saladini F, Palatini P. Validation of the Visomat Comfort form device for home blood pressure measurement according to the International Protocol. Blood Press Monit 2010;15(1):63-6
56 Wan Y, Pan F, Liu Y, Liang Y, Yang Z, Zhao H, Xu Y. Validation of the Andon KD-391 semiautomated blood pressure monitor in adults according to the International Protocol. Blood Press Monit 2009;14:181-4
57 Huang QF, Wang J, Sheng CS, Zhang NN, Li Y, Wang JG. Validation of the ANDON KD-5915 blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol. Blood Press Monit 2010;15(4):232-4
58 Coleman A, Steel S, deGreeff A, Shennan A. Validation of the Lloyds Pharmacy BP11 oscillometric blood pressure monitor according to the International Protocol of the European Society of Hypertension. Blood Press Monit 2010;15(3):163-6
59 Pan F, Wan Y, Chen W, Li N, Tong W, Xu Y. Validation of the Andon KD-575 automated blood pressure monitor according to the European Society of Hypertension International protocol in adults. Blood Press Monit 2010;15(3):167-70.
60 Zeng WF, Huang QF, Sheng GS, Li Y, Wang JG. Validation of the Kingyield BP101H blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol. Blood Press Monit 2010;15(6):329-31.
61 Stergiou GS, Tzamouranis D, Nasothimiou EG, Karpettas N, Protogerou A. Are there really differences between home and daytime ambulatory blood pressure? Comparison using a novel dual-mode ambulatory and home monitor. J Hum Hypertens 2010;24(3):207-12.
62 Ragazzo F, Saladini F, Palatini P. Validation of the Microlife WatchBP O3 device for clinic, home, and ambulatory blood pressure measurement, according to the International Protocol. Blood Press Monit 2010;15(1):59-62.
63 Masiero S, Fania C, Palatini P. Validation of the UEBE Visomat Double Comfort upper arm blood pressure monitor, in auscultation mode, for clinic use and self-measurement in a general population, according to the European Society of Hypertension International Protocol revision 2010. Blood Press Monit 2011;16(4):208-10.
64 Masiero S, Fania C, Palatini P. Validation of the UEBE Visomat Double Comfort upper arm blood pressure monitor, in oscillometric mode, for clinic use and self-measurement in a general population according to the European Society of Hypertension International Protocol, revision 2010. Blood Press Monit 2011;16(5):262-4
65 Topouchian J, Agnoletti D, Blacher J, Youssef A, Ibanez I, Khabouth J, Khawaja S, Beaino L, Asmar R. Validation of four automatic devices for selfmeasurement of blood pressure according to the international protocol of the European Society of Hypertension. Vascular Health and Risk Management 2011:7;709-17 doi: 10.2147/VHRM.S27193
66 Chung Y, de Greeff A, Shennan A. Validation and Compliance of a Home Monitoring Device in Pregnancy: Microlife WatchBP Home. Hypertens Pregnancy 2009;28(3):348-59.
67 Liu WJ, Li SG, Song Z, Gong W. Validation of the TRANSTEK blood pressure monitor TMB-986 for home blood pressure monitoring according to the International Protocol. Blood Press Monit 2010;15(5):278-80 doi: 10.1097/MBP.0b013e32833e43ca
68 Yi J, Wan Y, Pan F, Yu X, Zhao H, Shang F, Xu Y. Validation of the Medipro MediCare 100f upper arm blood pressure monitor, for self-measurement, according to the European Society of Hypertension International Protocol revision 2010. Blood Press Monit 2011;16(4):197-9. doi: 10.1097/MBP.0b013e328346d715
69 Bonso E, Dorigatti F, Palatini P. Validation of Panasonic EW3106 and EW3109 devices for blood pressure measurement according to the International Protocol. Blood Press Monit 2010;15(1):55-8. doi: 10.1097/MBP.0b013e32833531b3
70 Chen C, Shang F, Wang J, Chen J, Ji N, Wan Y. Validation of the iHealth BP3 upper-arm blood pressure monitor, for clinic use and self-measurement, according to the European Society of Hypertension International Protocol revision 2010. Blood Press Monit 2012;17(6):253-6. doi: 10.1097/MBP.0b013e32835b9ecb
71 Takahashi H, Yoshika M, Yokoi T. Validation of home blood pressure-monitoring devices, Omron HEM-1020 and Omron i-Q132 (HEM-1010-E), according to the European Society of Hypertension International Protocol. Blood Press Monit 2011;16(4):203-7. doi: 10.1097/MBP.0b013e328348b688
72 Palatini P. Validation of the Foracare Fora D30 upper arm blood pressure monitor, for self measurement, according to the European Society of Hypertension International Protocol 2002 [Internet]. Dublin: dablEducational Trust; 2010 Apr 05. 6 p. Available from: http://www.dableducational.org/Publications/2010/ESH-IP 2002 Validation of Foracare Fora D30.pdf
73 Masiero S, Fania C, Palatini P. Validation of the UEBE Visomat Double Comfort upper arm blood pressure monitor, in auscultation mode, for clinic use and self measurement in a general population, according to the European Society of Hypertension International Protocol revision 2010 [Internet]. Dublin: dablEducational Trust; 2011 Apr 27. 4 p. Available from: http://www.dableducational.org/Publications/2011/ESH-IP 2010 Validation of UEBE Visomat_Double_Comfort (Auscultatory Mode).pdf.
74 Masiero S, Fania C, Palatini P. Validation of the UEBE Visomat Double Comfort upper arm blood pressure monitor, in oscillometry mode, for clinic use and self measurement in a general population, according to the European Society of Hypertension International Protocol revision 2010 [Internet]. Dublin: dablEducational Trust; 2011 Apr 27. 4 p. Available from: http://www.dableducational.org/Publications/2011/ESH-IP 2010 Validation of UEBE Visomat_Double_Comfort (Oscillometric Mode).pdf.
75 Ding D. Validation of the Foracare Fora D40b upper arm blood pressure monitor, for self measurement, according to the European Society of Hypertension International Protocol Revision 2010 [Internet]. Dublin: dablEducational Trust; 2011 Jul 29. 7 p. Available from: http://www.dableducational.org/Publications/2011/ESH-IP 2010 Validation of Foracare Fora D40b.pdf
76 de Greeff A, Shennan AH. Validation of the Nissei DSK-1011 upper arm blood pressure monitor, for clinic use and self measurement in a general population, according to the European Society of Hypertension International Protocol revision 2010 [Internet]. Dublin: dablEducational Trust; 2011 Sep 01. 9 p. Available from: http://www.dableducational.org/Publications/2011/ESH-IP 2010 Validation of Nissei DSK-1011.pdf.
77 de Greeff A, Shennan AH. Validation of the Nissei DSK-1031 upper arm oscillometric blood pressure monitor intended for clinic use and self measurement in a general population, according to the European Society of Hypertension International Protocol revision 2010 [Internet]. Dublin: dablEducational Trust; 2011 Oct 28. 3 p. Available from: http://www.dableducational.org/Publications/2011/ESH-IP 2010 Validation of Nissei DSK-1031.pdf.
78 Takahashi H. Validation of the Omron M3W upper arm blood pressure monitor, in oscillometry mode, for clinic use and self measurement in a general population, according to the European Society of Hypertension International Protocol revision 2010 [Internet]. Dublin: dablEducational Trust; 2012 Mar 01. 4 p. Available from: http://www.dableducational.org/Publications/2012/ESH-IP 2010 Validation of Omron M3W (HEM-7202-E).pdf
79 Takahashi H. Validation of the Omron M6W upper arm blood pressure monitor, in oscillometry mode, for self measurement in a general population, according to the European Society of Hypertension International Protocol revision 2010 [Internet]. Dublin: dablEducational Trust; 2012 Mar 01. 4 p. Available from: http://www.dableducational.org/Publications/2012/ESH-IP 2010 Validation of Omron M6W (HEM-7213-E).pdf
80 Asmar R. Validation of the OMRON M6 COMFORT (HEM-7221-E8) Upper Arm blood pressure monitor, for self/home measurement, according to the revised (2010) European Society of Hypertension International Protocol. [Internet]. Dublin: dablEducational Trust; 2012 Jun 06. 3 p. Available from: http://www.dableducational.org/Publications/2012/ESH-IP 2010 Validation of Omron M6 Comfort (HEM-7221-E8).pdf
81 Takahashi H. Validation of the Omron i-Q142(HEM-1040-E), an upper arm blood pressure monitor, in oscillometry mode, for clinic use and self measurement in a general population, according to the European Society of Hypertension International Protocol revision 2010 [Internet]. Dublin: dablEducational Trust; 2012 Jun 07. 4 p. Available from: http://www.dableducational.org/Publications/2012/ESH-IP 2010 Validation of Omron i-Q142 (HEM-1040-E).pdf
82 Ding D. Validation of the FORA P30 Plus Upper Arm Blood Pressure Monitor, for Clinic Use and Self/Home Measurement, According to the European Society of Hypertension International Protocol Revision 2010 [Internet]. Dublin: dablEducational Trust; 2012 Oct 19. 6 p. Available from: http://www.dableducational.org/Publications/2012/ESH-IP 2010 Validation of Foracare Fora P30 Plus.pdf
83 Takahashi H, Yokoi T, Yoshika M. Validation of the OMRON HEM-7251G upper arm blood pressure monitor, in oscillometry mode, for clinic use and self measurement in a general population, according to the European Society of Hypertension International Protocol revision 2010 [Internet]. Dublin: dablEducational Trust; 2013 Feb 01. 4 p. Available from: http://www.dableducational.org/Publications/2013/ESH-IP 2010 Validation of Omron HEM-7251G.pdf
84 Zeng WF, Kang YY, Liu M, Li Y, Wang JG. Validation of the A&D UA-1020 upper-arm blood pressure monitor for home blood pressure monitoring according to the British Hypertension Society Protocol. Blood Press Monit 2013;18(3):177-81. doi: 10.1097/MBP.0b013e32836141ca
85 Shang F, Zhu Y, Zhu Z, Liu L, Wan Y. Validation of the iHealth BP5 wireless upper arm blood pressure monitor for self-measurement according to the European Society of Hypertension International Protocol revision 2010. Blood Press Monit 2013;18(5):278-81. doi: 10.1097/MBP.0b013e3283638f04
86 Palatini P. Validation of the Thermor Bios BP215 upper arm blood pressure monitor, for clinic use and self measurement, according to the European Society of Hypertension International Protocol revision 2010 [Internet]. Dublin: dablEducational Trust; 2013 Oct 09. 11 p. Available from: http://www.dableducational.org/Publications/2013/ESH-IP 2010 Validation of Thermor Bios BD215.pdf
87 de Greeff A, Shennan AH. Validation of the Tensoval Duo Control II blood pressure monitor for clinic use and self-measurement according to the British Hypertension Society protocol and the European Society of Hypertension International Protocol Revision 2010. Blood Press Monit 2013;18(3):161-6. doi: 10.1097/MBP.0b013e328360fb52
88 Takahashi H, Yokoi T, Yoshika M. Validation of the OMRON HEM-7130 upper arm blood pressure monitor, in oscillometry mode, for clinic use and self measurement in a general population, according to the European Society of Hypertension International Protocol revision 2010 [Internet]. Dublin: dablEducational Trust; 2013 Nov 14. 4 p. Available from: http://www.dableducational.org/Publications/2013/ESH-IP 2010 Validation of Omron HEM-7130.pdf
89 Takahashi H, Yokoi T, Yoshika M. Validation of the OMRON HEM-7320F upper arm blood pressure monitor, in oscillometry mode, for clinic use and self measurement in a general population, according to the European Society of Hypertension International Protocol revision 2010 [Internet]. Dublin: dablEducational Trust; 2013 Nov 14. 4 p. Available from: http://www.dableducational.org/Publications/2013/ESH-IP 2010 Validation of Omron HEM-7500F.pdf
90 Takahashi H, Yokoi T, Yoshika M. Validation of the OMRON HEM-7500F upper arm blood pressure monitor, in oscillometry mode, for clinic use and self measurement in a general population, according to the European Society of Hypertension International Protocol revision 2010 [Internet]. Dublin: dablEducational Trust; 2013 Nov 14. 4 p. Available from: http://www.dableducational.org/Publications/2013/ESH-IP 2010 Validation of Omron HEM-7500F.pdf
91 Ding D. Validation of the Taidoc U-Right TD-3124 upper arm blood pressure monitor, for self measurement, according to the European Society of Hypertension International Protocol revision 2010 [Internet]. Dublin: dablEducational Trust; 2013 Dec 03. 11 p. Available from: http://www.dableducational.org/Publications/2013/ESH-IP 2010 Validation of Taidoc U-Right TD-3124.pdf
92 Takahashi H, Yokoi T, Yoshika M. Validation of the OMRON M6 Comfort (HEM-7321-E) upper arm blood pressure monitor, in oscillometry mode, for clinic use and self measurement in a general population, according to the European Society of Hypertension International Protocol revision 2010 [Internet]. Dublin: dablEducational Trust; 2014 Jan 22. 4 p. Available from: http://www.dableducational.org/Publications/2014/ESH-IP 2010 Validation of Omron M6 Comfort (HEM-7321-E).pdf
93 Takahashi H, Yokoi T, Yoshika M. Validation of the OMRON M6 AC (HEM-7322-E) upper arm blood pressure monitor, in oscillometry mode, for clinic use and self measurement in a general population, according to the European Society of Hypertension International Protocol revision 2010 [Internet]. Dublin: dablEducational Trust; 2014 Jan 22. 4 p. Available from: http://www.dableducational.org/Publications/2014/ESH-IP 2010 Validation of Omron M6 AC (HEM-7322-E).pdf
94 Ding D. Validation of the Foracare Diamond Cuff BP (Test N'Go BP) upper arm blood pressure monitor, for self measurement, according to the European Society of Hypertension International Protocol revision 2010 [Internet]. Dublin: dablEducational Trust; 2014 May 02. 9 p. Available from: http://www.dableducational.org/Publications/2014/ESH-IP 2010 Validation of Foracare Diamond Cuff BP.pdf
95 Guo WG1, Li BL, He Y, Xue YS, Wang HY, Zheng QS, Xiang DC. Validation of the Andon KD-5917 automatic upper arm blood pressure monitor, for clinic use and self-measurement, according to the European Society of Hypertension International Protocol revision 2010. Blood Press Monit. Blood Press Monit 2014;19(4):242-5. doi: 10.1097/MBP.0000000000000048
96 Benetti E1, Fania C, Palatini P. Validation of the A&D BP UA-651 device for home blood pressure measurement according to the European Society of Hypertension International Protocol revision 2010. Blood Press Monit 2014;19(1):50-3. doi: 10.1097/MBP.0000000000000020
97 Benetti E1, Fania C, Palatini P. Validation of the A&D UA-651 upper arm blood pressure monitor, for self measurement, according to the European Society of Hypertension International Protocol revision 2010 [Internet]. Dublin: dablEducational Trust; 2014 Jul 15. 8 p. Available from: http://www.dableducational.org/Publications/2014/ESH-IP 2010 Validation of AnD UA-651.pdf.

Wrist Devices for Self-measurement of Blood Pressure

Recommendations for all wrist devices are based on their being positioned strictly according to manufacturer instructions.

For a complete list of devices see our Device Index and for discontinued devices see our Discontinued Devices Index.

New to the market New to the website  
Device Mode AAMI BHS ESH 2002 ESH 2010 Circumstance Recommendation Ref  
A&D UB-511 Wrist   Pass     At rest Questionable 7  
Braun BP 2000 (BBP2000) Wrist Pass A/A Pass   BP W100 Equivalence; Supine position Recommended E109  
Braun BP 2200 (BBP2200) Wrist Pass A/A Pass   BP W100 Equivalence; Supine position Recommended E110  
Braun BP VitalScan Plus 1650 Wrist     Pass   At rest Recommended 11  
Braun BP VitalScan Plus 1700 Wrist     Pass   BP1650 Equivalence Recommended E24  
Braun BP VitalScan Plus 1750 Wrist     Pass   BP1650 Equivalence Recommended E25  
Braun BPW4100 Wrist       Pass BP210 Equivalence Recommended E117
Braun BPW4300 Wrist       Pass BP210 Equivalence Recommended E118
Citizen CH-656C Wrist     Pass   At rest Recommended 10  
Health & Life HL168JD Wrist     Pass   At rest Recommended 16  
iHealth BP7 (KD-972) Wrist       Pass At rest Recommended 28  
Kingyield BP210 Wrist       Pass Study (22) extended to ESH-IP 2010 requirements Recommended 24  
Medel Replay (91914REPLAY) Wrist Pass B/B Pass   SAW-102 Equivalence Recommended E34  
Microlife BP W100 Wrist Pass A/A Pass   Supine position Recommended 14  
Microlife BP W200-1 Wrist     Pass   MAM averaging and supine position Recommended 12  
Nissei WSK-1011 Wrist       Pass At rest Recommended 21  
Nissei WSK-1021 Wrist       Pass WSK-1011 Equivalence Recommended E99  
Omron 637IT
(HEM-637-E)
Wrist Pass B/A Fail   Abstract; BHS 'pass' incorrectly reported Questionable 3  
        AD Hoc protocol,
+ position sensor, std. protocol projections inconclusive
Questionable 1
    Pass   Adults Recommended 4  
    Pass   Obese Adults Recommended 4  
    Pass   Elderly Recommended 5  
Omron R3 Intellisense
(HEM-6021-E)
Wrist     Pass   R3-I Plus (HEM-6022-E)
Equivalence
Recommended E47  
Omron R3-I Plus
(HEM-6022-E)
Wrist     Pass   At rest Recommended 18  
Omron R5-I
(HEM-630-E)
Wrist     Pass   Elderly Population Recommended 9  
Omron R6
(HEM-6000-E)
Wrist     Pass   R7 (HEM-637-IT) Equivalence Recommended E22  
Omron R6
(HEM-6000-E7)
Wrist     Pass   R7 (HEM-637-IT) Equivalence
New sensor
Recommended E39  
Omron R6
(HEM-6052-E)
Wrist     Pass   R7 (HEM-637-IT) Equivalence Recommended E62  
Omron R6
(HEM-6052-E7)
Wrist     Pass   R7 (HEM-637-IT) Equivalence
New sensor
Recommended E63  
Omron R7
(HEM-637-E7)
Wrist     Pass   R7 (HEM-637-IT) Equivalence
New sensor
Recommended E61  
Omron R7
(HEM-637-IT)
Wrist     Pass   At rest Recommended 6  
Omron RS1
(HEM-6120-E)
Wrist       Pass RS3
(HEM-6130-E) Equivalence
Recommended E100  
Omron RS2
(HEM-6121-E)
Wrist       Pass RS3
(HEM-6130-E) Equivalence
Recommended E101  
Omron RS3
(HEM-6130-E)
Wrist       Pass At rest Recommended 26  
Omron RS6
(HEM-6221-E)
Wrist       Pass At rest Recommended 27  
Omron RS8
(HEM-6310F-E)
Wrist       Pass At rest Recommended 29  
Omron RX3
(HEM-640-E)
Wrist     Pass   Abstract only Questionable 2  
Pic Solution (Artsana)
Pic Indolor (Artsana)
Self Check
Wrist     Pass   Travel Check Equivalence Recommended E32  
Pic Solution (Artsana)
Pic Indolor (Artsana)
Travel Check
Wrist     Pass   At rest Recommended 17  
Rossmax S150 Wrist       Pass Study (23) protocol violations corrected Recommended 25  
Samsung SBM-100A Wrist     Fail   At rest Not Recommended 8  
Sensacare SAW-102 (Standard) Wrist Pass B/B Pass   At rest Recommended 13  
Transtek TMB-988 Wrist     Pass   At rest Recommended 20  
UEBE Visomat Handy Wrist     Pass   At rest Recommended 19  
Visicor HM40 Wrist     Pass   Supine position Recommended 15  

References for Validation of Wrist Devices for Self-measurement of Blood Pressure

1 Yarrows SA. Comparison of the Omron HEM-637 wrist monitor to the auscultation method with the wrist position sensor on or disabled. Am J Hypertens 2004;17(1):54-8. Erratum in. Am J Hypertens 2004;17(4):383.
2 El-Assaad MA, Orobinskaya LV, Topouchian JA, Asmar RG. Validation of the Omron® RX-3 Blood Pressure Measuring Device at the wrist level according to the International Protocol of the European Society of Hypertension [abstract]. Am J Hypertens 2005;18(S4):29A Abstract P58
3 Altunkan Ş, Iliman N, Altunkan E Accuracy of the new wrist blood pressure monitor (Omron 637 IT), for blood pressure measurement [abstract]. J Hypertens 2003;21(Suppl 4):S22 Abstract P1.6
4 Altunkan Ş, Öztas K, Altunkan E. Validation of the Omron 637IT wrist blood pressure measuring device with a position sensor according to the International Protocol in adults and obese adults. Blood Press Monit 2006;11:79-85
5 Altunkan Ş, Altunkan E. Validation of the Omron 637IT wrist blood pressure measuring device with a position sensor according to the International Protocol in the elderly. Blood Press Monit 2006;11:97-102
6 Topouchian JA, El Assaad MA, Orobinskaia LV, El Feghali RN, Asmar RG. Validation of two automatic devices for self-measurement of blood pressure according to the International Protocol of the European Society of Hypertension: the Omron M6 (HEM-7001-E) and the Omron R7 (HEM 637-IT). Blood Press Monit 2006;11:165-71
7 Angeli F, Sardone M, Angeli E, Repaci S, Gattobigio R, Verdecchia P. Validation of the A&D wrist-cuff UB-511 (UB-512) device for self-measurement of blood pressure. Blood Press Monit 2006;11:349-54
8 Altunkan Ş, Iliman N, Altunkan E. Validation of the Samsung SBM-100A and Microlife BP 3BU1-5 wrist blood pressure measuring devices in adults according to the International Protocol. Blood Press Monit 2007;12:119-25
9 Omboni S, Riva I, Giglio I, Caldara G, Groppelli A, Parati G. Validation of the Omron M5-I, R5-I and HEM-907 automated blood pressure monitors in elderly individuals according to the International Protocol of the European Society of Hypertension. Blood Press Monit 2007;12:233-42
10 Cotte UV, Faltenbacher VH, von Willich W, Bogner JR. Trial of validation of two devices for self-measurement of blood pressure according to the European Society of Hypertension International Protocol: the Citizen CH-432B and the Citizen CH-656C. Blood Press Monit 2008;13:55-62
11 Nolly H, Osso P, Nolly A, Silva M, Nolly M, Romero M. Self-measurement of blood pressure: validation of the Braun BP VitalScan Plus 1650 monitor according to the European Society of Hypertension International Protocol. Blood Press Monit 2008;13:101-6
12 Palatini P, Dorigatti F, Bonso E, Ragazzo F. Validation of the Microlife BP W200-1 wrist device for blood pressure measurement. Blood Press Monit 2008;13:295-8
13 Zaetta V, Longo D, Perkovic D, Perfetti P, Gabrieli A, Pratticò F, Winnicki M. Validation of the SAW-102 wrist home blood pressure monitor according to the protocols of the British Hypertension Society, the Association for the Advancement of Medical Instrumentation, and the European Society of Hypertension. Blood Press Monit 2009;14:32-6
14 Palatini P, Dorigatti F, Bonso E, Ragazzo F. Validation of Microlife BP W100 wrist device assessed according to the European Society of Hypertension and the British Hypertension Society protocols. Blood Press Monit 2009;14:41-4
15 Dorigatti F, Bonso E, Saladini F, Palatini P. Validation of the visocor HM40 wrist blood pressure measuring device according to the International Protocol. Blood Press Monit 2009;14:83-6
16 Sheng CS, Huang QF, Wang J, Zhang Y, Li Y, Wang JG. Validation of the Health & Life HL168JD wrist blood pressure monitor for home blood pressure monitoring according to the International Protocol. Blood Press Monit 2009;14:125-7
17 Germano G, Psimenos A, Sarullo F, Venditti A, Pecchioli V, Asmar R. Validation of four automatic devices for self-measurement of blood pressure according to the International Protocol: The Pic Indolor Personal Check, Comfort Check, My Check and Travel Check. Blood Pressure 2009;18 (Suppl 1):15-23
18 Asmar R, Khabouth J, Topouchian J, El Feghali R, Mattar J. Validation of three automatic devices for self-measurement of blood pressure according to the International Protocol: The Omron M3 Intellisense (HEM-7051-E), the Omron M2 Compact (HEM 7102-E), and the Omron R3-I Plus (HEM 6022-E). Blood Press Monit 2010;15(1):49-54 doi: 10.1097/MBP.0b013e3283354b11
19 Saladini F, Benetti E, Palatini P. Accuracy of the visomat handy wrist blood pressure measuring device according to the International Protocol. Blood Press Monit 2010;15(5):281-4 doi: 10.1097/MBP.0b013e32833e50f2
20 Tian HY, Liu WJ, Li SG, Song Z, Gong W. Validation of the Transtek TMB-988 wrist blood pressure monitor for home blood pressure monitoring according to the International Protocol. Blood Press Monit 2010;15(6):326-8 doi: 10.1097/MBP.0b013e32833f56fb
21 de Greeff A, Shennan AH. Validation of the Nissei WSK-1011 wrist blood pressure monitor, for self measurement, according to the European Society of Hypertension International Protocol revision 2010 [Internet]. Dublin: dablEducational Trust; 2011 Sep 09 9 p. Available from: http://www.dableducational.org/Publications/2011/ESH-IP 2010 Validation of Nissei WSK-1011.pdf.
22 Zeng WF, Huang QF, Sheng CS, Li Y, Wang JG. Validation of the Kingyield BP210 wrist blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension-International Protocol. Blood Press Monit. Blood Press Monit 2012;17(5):42-4 doi: 10.1097/MBP.0b013e32834f8301
23 Zeng WF, Huang QF, Sheng CS, Li Y, Wang JG. Validation of the Rossmax S150 wrist blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010. Blood Press Monit 2012;17(5):204-6 doi: 10.1097/MBP.0b013e328359c426
24 Zeng WF, Huang QF, Sheng CS, Li Y, Wang JG. Validation of the Kingyield BP210 wrist blood pressure monitor, for self measurement, according to the European Society of Hypertension International Protocol revision 2010 [Internet]. Dublin: dablEducational Trust; 2013 Jan 07. 7 p. Available from: http://www.dableducational.org/Publications/2013/ESH-IP 2010 Validation of Kingyield BP210.pdf
25 Zeng WF, Huang QF, Sheng CS, Li Y, Wang JG. Validation of the Rossmax S150 wrist blood pressure monitor, for self measurement, according to the European Society of Hypertension International Protocol revision 2010 [Internet]. Dublin: dablEducational Trust; 2013 Apr 08. 8 p. Available from: http://www.dableducational.org/Publications/2013/ESH-IP 2010 Validation of Rossmax S150.pdf
26 Takahashi H, Yokoi T, Yoshika M. Validation of the OMRON RS3 (HEM-6130-E) wrist blood pressure monitor, in oscillometry mode, for clinic use and self measurement in a general population, according to the European Society of Hypertension International Protocol revision 2010 [Internet]. Dublin: dablEducational Trust; 2013 Feb 01. 4 p. Available from: http://www.dableducational.org/Publications/2013/ESH-IP 2010 Validation of Omron RS3 (HEM-6130-E).pdf
27 Takahashi H, Yokoi T, Yoshika M. Validation of the OMRON RS6 (HEM-6221-E) wrist blood pressure monitor, in oscillometry mode, for clinic use and self measurement in a general population, according to the European Society of Hypertension International Protocol revision 2010 [Internet]. Dublin: dablEducational Trust; 2013 Feb 01.4 p. Available from: http://www.dableducational.org/Publications/2013/ESH-IP 2010 Validation of Omron RS6 (HEM-6221-E).pdf
28 Wang Q, Zhao H, Chen W, Li N, Wan Y. Validation of the iHealth BP7 wrist blood pressure monitor, for self-measurement, according to the European Society of Hypertension International Protocol revision 2010. Blood Press Monit. 2014;19(1):54-7. doi: 10.1097/MBP.0000000000000017.
29 Takahashi H, Yokoi T, Yoshika M. Validation of the OMRON RS8 (HEM-6310F-E) wrist blood pressure monitor, in oscillometry mode, for clinic use and self measurement in a general population, according to the European Society of Hypertension International Protocol revision 2010 [Internet]. Dublin: dablEducational Trust; 2014 Feb 27.4 p. Available from: http://www.dableducational.org/Publications/2014/ESH-IP 2010 Validation of Omron RS8 (HEM-6310F-E).pdf

Devices for Measuring Blood Pressure in the Community

For a complete list of devices see our Device Index and for discontinued devices see our Discontinued Devices Index.

New to the market New to the website  
Device Mode AAMI BHS ESH 2002 ESH 2010 Circumstance Recommendation Ref  
A&D TM-2655 Osc Pass A/A     Methods poorly explained Questionable 3  
Keito K6 Wrist         Standing; Fail Ad Hoc protocol Questionable 2  
Pharma-Smart PS-2000 Cuff Pass A/A     At rest; BHS protocol violations Questionable 1  

References for Validation of Devices for Measuring Blood Pressure in the Community

1 Alpert BS. Validation of the Pharma-Smart PS-2000 public use blood pressure monitor Blood Press Monit 2004;9:19-23
2 Staal EM, Nygard OK, Omvik P, Gerdts E. Blood pressure measurements by the Keito machine. Evaluation versus office blood pressure by physicians Blood Press Monit 2004;9:167-72
3 Kobalava ZD, Kotovskaya YV, Babaeva LA, Moiseev VS. Validation of oscillometric device for blood pressure measurement Blood Press Monit 2006;11:87-90