| Device |
Mode |
AAMI |
BHS |
ESH |
Circumstance |
Recommendation Ref |
|
| A&D TM-2430 |
Osc |
Pass |
A/A |
|
At rest |
Recommended 6 |
|
| Advanced Biosensor AM5600 |
Aus |
Pass |
|
|
In children; AAMI Method 1 only; BHS grading not appropriate; contradictions |
Questionable 28 |
 |
| BpLab |
Osc |
|
|
Pass |
At rest |
Questionable 19 |
|
| Cardiette BP One |
Osc |
|
A/A |
|
At rest |
Recommended 25 |
|
| HealthStats BPro |
Wrist |
Pass |
|
Pass |
Study details omitted |
Not Recommended 26 |
|
IEM Mobil O Graph (version 12) |
Osc |
Pass |
B/A |
|
At rest |
Recommended 14 |
|
| Jotatec P24B |
Osc |
|
|
Pass |
Abstract Only |
Questionable 27 |
|
| Meditech ABPM-04 |
Osc |
Pass |
B/B |
|
At rest |
Recommended 1 |
|
| Meditech ABPM-05 |
Osc |
Pass |
B/B |
|
ABPM-04 Equivalence |
Recommended E14 |
|
| Microlife WatchBP O3 3MZ0 |
Osc |
|
|
Pass |
At rest |
Recommended FTS |
|
| Nissei DS-250 |
Osc |
|
|
Pass |
Abstract; 'Passes' incorrectly reported |
Questionable 17 |
|
| Aus |
|
|
Pass |
| Save 33, Model 2 |
Osc |
Pass |
B/B |
|
At rest |
Recommended 23 |
|
| Seinex SE-25M |
Osc |
Pass |
A/B |
|
Analysis violations (AAMI & BHS); BHS 'pass' incorrectly reported |
Questionable 16 |
|
| Spacelabs 90207 |
Osc |
Pass |
B/B |
|
At rest |
Recommended 2 |
|
| Pass |
B/B |
|
In pregnancy |
Recommended 3 |
| Pass |
A/B |
|
Elderly standing & sitting SBP < 161 mmHg |
Recommended 4 |
| Pass |
A/C |
|
In pregnancy |
Not Recommended 7 |
| Pass |
B/C |
|
In pregnancy |
Not Recommended 8 |
| Fail |
D/D |
|
In pre-eclampsia |
Not Recommended 9 |
| Pass |
C/C |
|
In pre-eclampsia |
Not Recommended 10 |
| Pass/ Fail |
C/D |
|
In children |
Not Recommended 11 |
| Pass |
A/D |
|
Elderly supine over all pressures |
Not Recommended 12 |
| Pass |
C/B |
|
During haemodialysis |
Not Recommended 13 |
| Spacelabs 90217 |
Osc |
Pass |
A/A |
|
At rest |
Recommended 5 |
|
| Suntech Medical AGILIS |
Osc |
|
|
Pass |
At rest |
Recommended 21 |
|
| Suntech Medical OSCAR 2 |
Osc |
|
|
Pass |
At rest |
Recommended 18 |
|
| |
A/A |
|
At rest |
Recommended 24 |
|
| Tensioday |
Osc |
Pass |
A/A |
|
At rest; grades of pressure; varying positions |
Recommended 15 |
|
| Tonoport V |
Osc |
|
|
Fail |
At rest |
Not Recommended 20 |
|
| |
|
Pass |
At rest |
Questionable 22 |
|
| 1 |
Barna I, Keszei A, Dunai A. Evaluation of Meditech ABPM-04 ambulatory blood pressure measuring device according to the British Hypertension Society protocol. Blood Press Monit. 1998;3:363-368 |
| 2 |
O'Brien E, Mee F, Atkins N, O'Malley K. Accuracy of the Spacelabs 90207 determined by to the British Hypertension Society Protocol. J Hypertens 1991;9(suppl 5):S25-S31 |
| 3 |
Shennan AH, Kissane J, de Swiet M. Validation of the Spacelabs 90207 ambulatory blood pressure monitoring in pregnancy. Br J Obstet & Gynae 1993;100:904-8 |
| 4 |
Iqbal P, Fotherby MD, Potter JF. Validation of the Spacelabs 90207 automatic non-invasive blood pressure monitor in elderly subjects. Blood Press Monit 1996;1:367-73 |
| 5 |
Baumgart P, Kamp J. Accuracy of the Spacelabs Medical 90217 ambulatory blood pressure monitor. Blood Press Monit 1998;3:303-307 |
| 6 |
Palatini P, Frigo G, Bertolo O, Roman E, Da Corta R, Winnicki M. Validation of the A&D TM-2430 device for ambulatory blood pressure monitoring and evaluation of performance according to subjects’ characteristics. Blood Press Monit 1998;3:255-260 |
| 7 |
O'Brien E, Mee F, Atkins N, Halligan A, O'Malley K. Accuracy of the Spacelabs 90207 ambulatory blood pressure measuring system in normotensive pregnant women determined by the British Hypertension Society Protocol. J Hypertens 1993;11(suppl 5):S282-S283 |
| 8 |
Franx A, van der Post JAM, van Montfrans GA, Bruinse HW. Comparison of an auscultatory versus an oscillometric ambulatory blood pressure monitor in normotensive, hypertensive and preeclamptic pregnancy. Hypertension in pregnancy 1997;16:187-202 |
| 9 |
Natarajan P, Shennan AH, Penny J, Halligan AW, de Swiet M, Anthony J. Comparison of auscultatory and oscillometric automated blood pressure monitors in the setting of preeclampsia. Am J Obstet Gynecol 1999;181:1203-1210 |
| 10 |
Shennan A, Haligan A, Gupta M, Taylor D, de Swiet M. Oscillometric blood pressure measurements in severe preeclampsia: validation of the Spacelabs 90207. Br J obstet & Gynaecol 1996;103:171-3 |
| 11 |
Belsha CW, Wells TG, Rice HB, Neaville WA, Berry PL. Accuracy of the Spacelabs 90207 ambulatory blood pressure monitor in children and adolescents. Blood Press Monit 1996;1:127-133 |
| 12 |
Iqbal P, Fotherby MD, Potter JF. Validation of the Spacelabs 90207 automatic non-invasive blood pressure monitor in elderly subjects. Blood Press Monit 1996;1:367-73 |
| 13 |
Peixoto AJ, Gray TA, Crowley ST. Validation of the Spacelabs 90207 ambulatory blood pressure device for hemodialysis patients. Blood Press Monit 1999;4:217-221 |
| 14 |
Jones CR, Taylor K, Chowienczyk P, Poston L, Shennan A. A validation of the Mobil O Graph (version 12) ambulatory blood pressure monitor. Blood Press Monit 2000;5:233-238 |
| 15 |
Nemeth Z, Moczar K, Deak G. Evaluation of the Tensioday ambulatory blood pressure monitor according to the the protocols of the British Hypertension society and the Association for the Advancement of Medical Instrumentation. Blood Press Monit 2002;7:191-197 |
| 16 |
Tannahill G, Gilmore C, Silke B. Validation of the upper arm algorithm for blood pressure determination incorporated in the Seinex digital devices using the AAMI and British Hypertension Society protocols Northern Ireland Medicine Today 2002;33:26-27 |
| 17 |
Altunkan Ş, Iliman N, Altunkan E. Validation of the Nissei DS-250 ambulatory blood pressure monitoring device according to the International Protocol J Hypertens 2003;21 (suppl 4):S22(P1.5) (Abstract) |
| 18 |
Jones, SC, Bilous M, Winship S, Finn P, Goodwin J. Validation of the OSCAR 2 oscillometric 24-hour ambulatory blood pressure monitor according to the International Protocol for the validation of blood pressure measuring devices. Blood Press Monit 2004;9:219-223 |
| 19 |
Rogoza AN. Accuracy of blood pressure estimation by automated monitors Functional diagnostics 2003;1:56-64. (In Russian) |
| 20 |
O'Brien E, Atkins N, Murphy A, Lyons S. Validation of the Tonoport V ambulatory blood pressure monitor according to the European Society of Hypertension International Protocol for validation of blood pressure measuring devices in adults Blood Press Monit 2003;8:255-260 |
| 21 |
Mallion JJM, Pierre H, Neuder Y, Ormezzano O, Baguet JP Validation of the AGILIS ambulatory blood pressure monitor according to the European society of Hypertension International Protocol for Validation of Blood Pressure Measuring devices in Adults Blood Press Monit 2005;10:97-101 |
| 22 |
Haensel A, Utech K, Langewitz W Validation of the TONOPORT V blood pressure measuring monitor in adults Journal of Human Hypertension 2005; 19 :745-749 |
| 23 |
De Gaudemaris R, White A, Pascal I, Siche JP, Baguet JP, Mallion JM. Évaluation du moniteur de pression artérielle en ambulatoire Save 33 modèle2. Arch Mal Coeur 1999;92:1133-1137 |
| 24 |
Goodwin J, Bilous M, Winship S, Finn P, Jones SC. Validation of the Oscar 2 oscillometric 24-h ambulatory blood pressure monitor according to the British Hypertension Society protocol Blood Pressure Monitoring 2007;12:113-117 |
| 25 |
Friz HP, Sega R, Facchetti R, Primit L, Beltrame L, Bombelli M. Accuracy evaluation of the 'Cardiette BP one' ambulatory blood pressure monitor Blood Press Monit 2008;13:107-110 |
| 26 |
Nair D, Tan SY, Gan HW, Lim SF, Tan J, Zhu M, Gao H, Chua NH, Peh WL, Mak KH. The use of ambulatory tonometric radial arterial wave capture to measure ambulatory blood pressure: the validation of a novel wrist-bound device in adults Journal of Human Hypertension 2008;22:220-222 (Research Letter) |
| 27 |
Octavio JA, Leal N, Contreras J, Octavio B, Cressa L, Valecillos I, Castellanos D, Fabiano D. Accuracy of Jotatec®-P24B device for teletransmitted ambulatory blood pressure monitoring Journal of Hypertension 2008;26 (suppl. 1):S493 (Abstract PS34/MON/60) |
| 28 |
Jones DP, Richey PA, Alpert BS. Validation of the AM5600 ambulatory blood pressure monitor in children and adolescents. Blood Press Monit 2008;13:349-351 |